Rapid~Flo & Slo~Flo Operating Principals & Float Orientation
 
Rapid~Flo Valve Part Filling

The minimum level is set by adjusting the length of the cord between the valve arm and the stop weight at the bottom of the cord. The maximum top up water level is set by the float orientation (see below for float orientation information).
Note: Hansen recommend all water tanks use a visible overflow.

 
Slo~Flo Valve Part Filling
The minimum level is set by adjusting the length of the cord between the valve arm and the stop weight at the bottom of the cord. The maximum top up water level is set by the float orientation (see below for float orientation information).
Note: Strainer & gooseneck not included. Pipework surrounding the Hansen Slo~Flo Valve should be fitted in accordance with local by-laws / council regulations.
Note: Hansen recommend all water tanks use a visible overflow.
 
Rapid~Flo & Slo~Flo Float Orientation
The orientation of the float determines the depth of the fill which can be either 50mm or 100mm.